Loading
Last 30 days · 8,640 frames · 160 runs · 9,171.9 Ah delivered
State of charge
State of health
Instantaneous power
Average temperature
Cell spread
Pack
68.1 V
22.4 A
Cells
20
3.392 – 3.418 V · 37 °C – 39 °C
Controller uptime
2d 11h
Contactor
Closed
Connected to the vehicle bus
Fault code
0Clear
BMS state
Charging
Immobiliser
Off
Samples
8,640
Last 30 days
Discharge sessions
86
74 charge sessions
Total SOC consumed
1,176.7%
Charge delivered
9,171.9 Ah
Longest discharge
18h 10m
56.2% used
| Session | Vehicle | Source | Started | Duration | Energy | Charge | Status |
|---|---|---|---|---|---|---|---|
| 1790144997-203(live) | KDB 192PCHJ-PK-0042 | SourceDC fast | 23 Sept 2026, 09:29 | Duration1h 18m | Energy2.775kWh | Charge12% → 94% | StatusLive |
| 1789970881-202 | KDB 192PCHJ-PK-0042 | SourceAC home | 21 Sept 2026, 09:08 | Duration4h 49m | Energy2.377kWh | Charge23% → 94% | StatusCompletedCharge complete |
| 1789889619-201 | KDB 192PCHJ-PK-0042 | SourceDC fast | 20 Sept 2026, 10:33 | Duration47m | Energy2.147kWh | Charge30% → 94% | StatusCompletedCharge complete |
| 1789829176-200 | KDB 192PCHJ-PK-0042 | SourceDC fast | 19 Sept 2026, 17:46 | Duration56m | Energy2.457kWh | Charge20% → 93% | StatusCompletedCharge complete |
| 1789757302-199 | KDB 192PCHJ-PK-0042 | SourceDC fast | 18 Sept 2026, 21:48 | Duration57m | Energy2.556kWh | Charge20% → 96% | StatusCompletedCharge complete |
| 1789626770-198 | KDB 192PCHJ-PK-0042 | SourceAC home | 17 Sept 2026, 09:32 | Duration3h 16m | Energy2.718kWh | Charge17% → 97% | StatusCompletedCharge complete |
| 1789512236-197 | KDB 192PCHJ-PK-0042 | SourceDC fast | 16 Sept 2026, 01:43 | Duration9m | Energy0.461kWh | Charge42% → 56% | StatusInterruptedOver temperature |
| 1789344156-196 | KDB 192PCHJ-PK-0042 | SourceAC home | 14 Sept 2026, 03:02 | Duration1h 8m | Energy0.582kWh | Charge30% → 47% | StatusInterruptedCharger fault |
| 1789179105-195 | KDB 192PCHJ-PK-0042 | SourceDC fast | 12 Sept 2026, 05:11 | Duration53m | Energy2.380kWh | Charge25% → 95% | StatusCompletedCharge complete |
| 1789008826-194 | KDB 192PCHJ-PK-0042 | SourceAC home | 10 Sept 2026, 05:53 | Duration2h 35m | Energy2.421kWh | Charge22% → 94% | StatusCompletedCharge complete |
Charge and discharge runs in the selected range
Trapezoidal integral of pack current
Trapezoidal integral of pack current
Trapezoidal integral of pack current
Trapezoidal integral of pack current
Trapezoidal integral of pack current
Trapezoidal integral of pack current
Trapezoidal integral of pack current
Trapezoidal integral of pack current
Trapezoidal integral of pack current
Trapezoidal integral of pack current
Trapezoidal integral of pack current
Trapezoidal integral of pack current
Trapezoidal integral of pack current
Trapezoidal integral of pack current
Trapezoidal integral of pack current
Trapezoidal integral of pack current
Trapezoidal integral of pack current
Trapezoidal integral of pack current
Trapezoidal integral of pack current
Trapezoidal integral of pack current
3.404 V
−1 mV · 37 °C
~42% charge
3.398 V
−7 mV · 38 °C
~41% charge
3.403 V
−2 mV · 38 °C
~42% charge
3.408 V
+3 mV · 38 °C
~42% charge
3.414 V
+9 mV · 38 °C
~43% charge
3.418 V
+13 mV · 38 °C
~44% charge
3.397 V
−8 mV · 38 °C
~41% charge
3.405 V
±0 mV · 38 °C
~42% charge
3.403 V
−2 mV · 39 °C
~42% charge
3.408 V
+3 mV · 39 °C
~42% charge
3.400 V
−5 mV · 39 °C
~41% charge
3.401 V
−4 mV · 39 °C
~42% charge
3.411 V
+6 mV · 38 °C
~43% charge
3.409 V
+4 mV · 39 °C
~43% charge
3.412 V
+7 mV · 38 °C
~43% charge
3.411 V
+6 mV · 38 °C
~43% charge
3.404 V
−1 mV · 38 °C
~42% charge
3.392 V
−13 mV · 38 °C
~40% charge
3.403 V
−2 mV · 38 °C
~42% charge
3.399 V
−6 mV · 38 °C
~41% charge