Loading vehicle

  1. Operator Console
  2. /
  3. Fleet
  4. /
  5. Units
  6. /
  7. KDB 192P

KDB 192P

Lufasi EV3 · Faith Wanjiku · last seen 2 min ago

ChargingOnline

Live

Charge

Speed

Power

Health

Pack temperature

Signal

Charge, 24 h

Odometer

9,241 km

Firmware

2.4.1

Pack temperature 38 °C; normal. Charge tone online.

Charge, last 24 hours

State of charge for KDB 192P over the last 24 hours

Charge sessions

Recent charge sessions for KDB 192P
SessionSourceStartedDurationEnergyChargeStatus
1790134197-203(live)SourceDC fast23 Sept 2026, 06:29Duration1h 7mEnergy2.775kWhCharge12% → 94%StatusLive
1789960081-202SourceAC home21 Sept 2026, 06:08Duration4h 49mEnergy2.377kWhCharge23% → 94%StatusCompletedCharge complete
1789878819-201SourceDC fast20 Sept 2026, 07:33Duration47mEnergy2.147kWhCharge30% → 94%StatusCompletedCharge complete
1789818376-200SourceDC fast19 Sept 2026, 14:46Duration56mEnergy2.457kWhCharge20% → 93%StatusCompletedCharge complete
1789746502-199SourceDC fast18 Sept 2026, 18:48Duration57mEnergy2.556kWhCharge20% → 96%StatusCompletedCharge complete
All sessions for KDB 192P

Telemetry

Pack voltage
68.1 V
Pack current
22.4 A
Cell spread
26 mV
GPS fix
good · ±6 m
Signal
−68 dBm
Buffered records
0
Energy in
741 kWh
Energy out
1,202 kWh
Regen / unmetered
44 kWh / 0 kWh
Device ID
CHJ-DEV-00A2
Asset ID
CHJ-AST-0042
Firmware
2.4.1

Hardware

Telematics device fitted to this vehicle

Device type
CHJ-T1 Telematics
Hardware version
T1 rev C
Device ID
CHJ-DEV-00A2
ESP32 MAC
24:0A:C4:84:E0:EA
Heartbeat interval
5 min
Telemetry interval
120 s
Speed limit
60 km/h

Firmware

ESP32
2.4.1
STM32
1.8.2
  1. ESP32 2.4.0 → 2.4.1

    2 h ago
    Installed

Activity

Events, faults and commands, newest first

  1. CELL_IMBALANCE_MINOR

    Warning

    Cell voltage spread at 25 mV - monitor recommended

    1 h ago
  2. Fault opened: CELL_IMBALANCE_MINOR

    Warning

    Cell spread 25 mV - monitoring · Unassigned

    1 h ago
  3. Rider message · Stanbic Portfolio Desk

    Confirmed

    "PAYMENT DUE TODAY"

    1 d ago
  4. Immobilise · Stanbic Portfolio Desk

    Accepted

    Payment overdue · immediately · Deferred until the vehicle stops

    2 d ago

Commands

Control
Diagnostics

Command history

  1. Rider messageConfirmed
    1 d ago

    "PAYMENT DUE TODAY"

    1. Sent: done
    2. Acknowledged: done
    3. Confirmed: done
    Stanbic Portfolio Deskcmd_seed_006
  2. ImmobiliseAccepted
    2 d ago

    Payment overdue · immediately

    1. Sent: done
    2. Acknowledged: done
    3. Confirmed: waiting
    Stanbic Portfolio Deskcmd_seed_007Deferred until the vehicle stops

Location

Loading map…

-1.3032, 36.8404

Inside: Nairobi CBD & Westlands

Contract & enforcement

  1. CurrentCurrent
  2. Reminder sentReminder sent
  3. Warning issuedWarning issued
  4. Speed restrictedSpeed restricted
  5. Immobilisation scheduledImmobilisation scheduled
  6. ImmobilisedImmobilised

Rung 2 of 6 · Reminder sent

36-Week Standard

Overdue

14 of 36 paid · 39% · 22 to go

Balance
Ksh 440,000
Weekly
Ksh 20,000
Next due
12 Sept 2026
Financier
Stanbic East Africa Capital

Battery pack

CHJ-PK-0042NMC · 3.2 kWh · In vehicle
State of health91%

288 cycles

  • 1Cell 1: 3.404 volts
  • 2Cell 2: 3.398 volts
  • 3Cell 3: 3.403 volts
  • 4Cell 4: 3.408 volts
  • 5Cell 5: 3.414 volts
  • 6Cell 6: 3.418 volts, highest
  • 7Cell 7: 3.397 volts
  • 8Cell 8: 3.405 volts
  • 9Cell 9: 3.403 volts
  • 10Cell 10: 3.408 volts
  • 11Cell 11: 3.400 volts
  • 12Cell 12: 3.401 volts
  • 13Cell 13: 3.411 volts
  • 14Cell 14: 3.409 volts
  • 15Cell 15: 3.412 volts
  • 16Cell 16: 3.411 volts
  • 17Cell 17: 3.404 volts
  • 18Cell 18: 3.392 volts, lowest
  • 19Cell 19: 3.403 volts
  • 20Cell 20: 3.399 volts

Min 3.392 VMax 3.418 VSpread 26 mV

Driver

Name
Faith Wanjiku
Phone
+254 722 019 847
Status
Active
KYC
Verified
On-time payments
74%
Last 7 days
51 trips · 640 km
Operator
Nairobi BodaBoda Alliance
Driver since
01 Dec 2025

Device events

Recent device events for KDB 192P

TimeEventSeverityReading
  • Time2 min agoEventDeep telemetrySeverityInfoReading42% · 68.1 V · 37 °CDetails for Deep telemetry

    Battery

    Charge
    42%
    Health
    91%
    Voltage
    68.1 V
    Current
    22.3 A
    Temperature
    37 °C
    Cell spread
    25 mV

    Device message

    Device message, field by field
    FieldValue
    DeviceCHJ-DEV-00A2
    Device time23 Sept 2026, 07:35
    Sequence0
    Message typeTelemetry deep
    Pack voltage68.1 V
    Pack current22.3 A
    Temperature37 °C
    Health91%
    Cell spread25 mV
    Cell voltages20 readings · 3,392–3,418 mV
    1. 1 3,408 mV
    2. 2 3,400 mV
    3. 3 3,409 mV
    4. 4 3,396 mV
    5. 5 3,403 mV
    6. 6 3,402 mV
    7. 7 3,392 mV
    8. 8 3,400 mV
    9. 9 3,395 mV
    10. 10 3,402 mV
    11. 11 3,418 mV
    12. 12 3,403 mV
    13. 13 3,405 mV
    14. 14 3,397 mV
    15. 15 3,413 mV
    16. 16 3,412 mV
    17. 17 3,405 mV
    18. 18 3,411 mV
    19. 19 3,405 mV
    20. 20 3,400 mV
    Connectivity firmware2.4.1
    Motor-control firmware1.8.2
  • Time2 min agoEventStandard telemetrySeverityInfoReading42% · 68.2 V · 38 °CDetails for Standard telemetry

    Battery

    Charge
    42%
    Health
    91%
    Voltage
    68.2 V
    Current
    22.8 A
    Temperature
    38 °C
    Cell spread
    23 mV

    Device message

    Device message, field by field
    FieldValue
    DeviceCHJ-DEV-00A2
    Device time23 Sept 2026, 07:35
    Sequence0
    Message typeTelemetry std
    Charge42%
    Speed0 km/h
    Latitude-1.303
    Longitude36.840
    Odometer9,241 km
    StateCharging
  • Time2 min agoEventHeartbeatSeverityInfoReadingHeartbeat · -68 dBm · 0 bufferedDetails for Heartbeat

    Device message

    Device message, field by field
    FieldValue
    DeviceCHJ-DEV-00A2
    Device time23 Sept 2026, 07:35
    Sequence0
    Message typeHeartbeat
    Signal-68 dBm
    Buffered records0
    Connectivity firmware2.4.1
  • Time4 min agoEventStandard telemetrySeverityInfoReading42% · 68.2 V · 38 °CDetails for Standard telemetry

    Battery

    Charge
    42%
    Health
    91%
    Voltage
    68.2 V
    Current
    23.1 A
    Temperature
    38 °C
    Cell spread
    23 mV

    Device message

    Device message, field by field
    FieldValue
    DeviceCHJ-DEV-00A2
    Device time23 Sept 2026, 07:33
    Sequence1
    Message typeTelemetry std
    Charge42%
    Speed0 km/h
    Latitude-1.303
    Longitude36.840
    Odometer9,241 km
    StateCharging
  • Time6 min agoEventStandard telemetrySeverityInfoReading40% · 68.1 V · 38 °CDetails for Standard telemetry

    Battery

    Charge
    40%
    Health
    91%
    Voltage
    68.1 V
    Current
    23.1 A
    Temperature
    38 °C
    Cell spread
    26 mV

    Device message

    Device message, field by field
    FieldValue
    DeviceCHJ-DEV-00A2
    Device time23 Sept 2026, 07:31
    Sequence2
    Message typeTelemetry std
    Charge40%
    Speed0 km/h
    Latitude-1.303
    Longitude36.840
    Odometer9,241 km
    StateCharging
  • Time7 min agoEventHeartbeatSeverityInfoReadingHeartbeat · -68 dBm · 0 bufferedDetails for Heartbeat

    Device message

    Device message, field by field
    FieldValue
    DeviceCHJ-DEV-00A2
    Device time23 Sept 2026, 07:30
    Sequence1
    Message typeHeartbeat
    Signal-68 dBm
    Buffered records0
    Connectivity firmware2.4.1
  • Time8 min agoEventStandard telemetrySeverityInfoReading40% · 68.0 V · 38 °CDetails for Standard telemetry

    Battery

    Charge
    40%
    Health
    91%
    Voltage
    68.0 V
    Current
    22.7 A
    Temperature
    38 °C
    Cell spread
    24 mV

    Device message

    Device message, field by field
    FieldValue
    DeviceCHJ-DEV-00A2
    Device time23 Sept 2026, 07:29
    Sequence3
    Message typeTelemetry std
    Charge40%
    Speed0 km/h
    Latitude-1.303
    Longitude36.840
    Odometer9,241 km
    StateCharging
  • Time10 min agoEventStandard telemetrySeverityInfoReading39% · 67.9 V · 38 °CDetails for Standard telemetry

    Battery

    Charge
    39%
    Health
    91%
    Voltage
    67.9 V
    Current
    22.3 A
    Temperature
    38 °C
    Cell spread
    26 mV

    Device message

    Device message, field by field
    FieldValue
    DeviceCHJ-DEV-00A2
    Device time23 Sept 2026, 07:27
    Sequence4
    Message typeTelemetry std
    Charge39%
    Speed0 km/h
    Latitude-1.303
    Longitude36.840
    Odometer9,241 km
    StateCharging
  • Time12 min agoEventStandard telemetrySeverityInfoReading38% · 68.0 V · 39 °CDetails for Standard telemetry

    Battery

    Charge
    38%
    Health
    91%
    Voltage
    68.0 V
    Current
    21.9 A
    Temperature
    39 °C
    Cell spread
    26 mV

    Device message

    Device message, field by field
    FieldValue
    DeviceCHJ-DEV-00A2
    Device time23 Sept 2026, 07:25
    Sequence5
    Message typeTelemetry std
    Charge38%
    Speed0 km/h
    Latitude-1.303
    Longitude36.840
    Odometer9,241 km
    StateCharging
  • Time12 min agoEventHeartbeatSeverityInfoReadingHeartbeat · -68 dBm · 0 bufferedDetails for Heartbeat

    Device message

    Device message, field by field
    FieldValue
    DeviceCHJ-DEV-00A2
    Device time23 Sept 2026, 07:25
    Sequence2
    Message typeHeartbeat
    Signal-68 dBm
    Buffered records0
    Connectivity firmware2.4.1
  • Time14 min agoEventStandard telemetrySeverityInfoReading38% · 68.0 V · 39 °CDetails for Standard telemetry

    Battery

    Charge
    38%
    Health
    91%
    Voltage
    68.0 V
    Current
    21.7 A
    Temperature
    39 °C
    Cell spread
    23 mV

    Device message

    Device message, field by field
    FieldValue
    DeviceCHJ-DEV-00A2
    Device time23 Sept 2026, 07:23
    Sequence6
    Message typeTelemetry std
    Charge38%
    Speed0 km/h
    Latitude-1.303
    Longitude36.840
    Odometer9,241 km
    StateCharging
  • Time16 min agoEventStandard telemetrySeverityInfoReading37% · 67.8 V · 39 °CDetails for Standard telemetry

    Battery

    Charge
    37%
    Health
    91%
    Voltage
    67.8 V
    Current
    22.7 A
    Temperature
    39 °C
    Cell spread
    25 mV

    Device message

    Device message, field by field
    FieldValue
    DeviceCHJ-DEV-00A2
    Device time23 Sept 2026, 07:21
    Sequence7
    Message typeTelemetry std
    Charge37%
    Speed0 km/h
    Latitude-1.303
    Longitude36.840
    Odometer9,241 km
    StateCharging
  • Time17 min agoEventHeartbeatSeverityInfoReadingHeartbeat · -68 dBm · 0 bufferedDetails for Heartbeat

    Device message

    Device message, field by field
    FieldValue
    DeviceCHJ-DEV-00A2
    Device time23 Sept 2026, 07:20
    Sequence3
    Message typeHeartbeat
    Signal-68 dBm
    Buffered records0
    Connectivity firmware2.4.1
  • Time18 min agoEventStandard telemetrySeverityInfoReading36% · 67.8 V · 37 °CDetails for Standard telemetry

    Battery

    Charge
    36%
    Health
    91%
    Voltage
    67.8 V
    Current
    22.6 A
    Temperature
    37 °C
    Cell spread
    26 mV

    Device message

    Device message, field by field
    FieldValue
    DeviceCHJ-DEV-00A2
    Device time23 Sept 2026, 07:19
    Sequence8
    Message typeTelemetry std
    Charge36%
    Speed0 km/h
    Latitude-1.303
    Longitude36.840
    Odometer9,241 km
    StateCharging
  • Time20 min agoEventStandard telemetrySeverityInfoReading35% · 67.7 V · 38 °CDetails for Standard telemetry

    Battery

    Charge
    35%
    Health
    91%
    Voltage
    67.7 V
    Current
    23.1 A
    Temperature
    38 °C
    Cell spread
    26 mV

    Device message

    Device message, field by field
    FieldValue
    DeviceCHJ-DEV-00A2
    Device time23 Sept 2026, 07:17
    Sequence9
    Message typeTelemetry std
    Charge35%
    Speed0 km/h
    Latitude-1.303
    Longitude36.840
    Odometer9,241 km
    StateCharging
  • Time22 min agoEventStandard telemetrySeverityInfoReading35% · 67.8 V · 37 °CDetails for Standard telemetry

    Battery

    Charge
    35%
    Health
    91%
    Voltage
    67.8 V
    Current
    23.1 A
    Temperature
    37 °C
    Cell spread
    26 mV

    Device message

    Device message, field by field
    FieldValue
    DeviceCHJ-DEV-00A2
    Device time23 Sept 2026, 07:15
    Sequence10
    Message typeTelemetry std
    Charge35%
    Speed0 km/h
    Latitude-1.303
    Longitude36.840
    Odometer9,241 km
    StateCharging
  • Time22 min agoEventHeartbeatSeverityInfoReadingHeartbeat · -68 dBm · 0 bufferedDetails for Heartbeat

    Device message

    Device message, field by field
    FieldValue
    DeviceCHJ-DEV-00A2
    Device time23 Sept 2026, 07:15
    Sequence4
    Message typeHeartbeat
    Signal-68 dBm
    Buffered records0
    Connectivity firmware2.4.1
  • Time24 min agoEventStandard telemetrySeverityInfoReading35% · 67.7 V · 38 °CDetails for Standard telemetry

    Battery

    Charge
    35%
    Health
    91%
    Voltage
    67.7 V
    Current
    22.0 A
    Temperature
    38 °C
    Cell spread
    23 mV

    Device message

    Device message, field by field
    FieldValue
    DeviceCHJ-DEV-00A2
    Device time23 Sept 2026, 07:13
    Sequence11
    Message typeTelemetry std
    Charge35%
    Speed0 km/h
    Latitude-1.303
    Longitude36.840
    Odometer9,241 km
    StateCharging
  • Time26 min agoEventStandard telemetrySeverityInfoReading34% · 67.8 V · 38 °CDetails for Standard telemetry

    Battery

    Charge
    34%
    Health
    91%
    Voltage
    67.8 V
    Current
    23.0 A
    Temperature
    38 °C
    Cell spread
    26 mV

    Device message

    Device message, field by field
    FieldValue
    DeviceCHJ-DEV-00A2
    Device time23 Sept 2026, 07:11
    Sequence12
    Message typeTelemetry std
    Charge34%
    Speed0 km/h
    Latitude-1.303
    Longitude36.840
    Odometer9,241 km
    StateCharging
  • Time27 min agoEventHeartbeatSeverityInfoReadingHeartbeat · -68 dBm · 0 bufferedDetails for Heartbeat

    Device message

    Device message, field by field
    FieldValue
    DeviceCHJ-DEV-00A2
    Device time23 Sept 2026, 07:10
    Sequence5
    Message typeHeartbeat
    Signal-68 dBm
    Buffered records0
    Connectivity firmware2.4.1
Showing 20 frames · Page 1 of 2
12