• Dashboard
    • Units
    • Map
    • Drivers
    • Batteries
    • Charging
    • Events
    • Faults
    • Map Replay
    • Log Audit
NKNaomi KamauOperator Console
  • Dashboard
    • Units
    • Map
    • Drivers
    • Batteries
    • Charging
    • Events
    • Faults
    • Map Replay
    • Log Audit

Loading vehicle

  1. Operator Console
  2. /
  3. Fleet
  4. /
  5. Units
  6. /
  7. KDA 441Y

KDA 441Y

Lufasi EV3 · James Ochieng · last seen just now

In useOnline

Live

Charge

Speed

Power

Health

Pack temperature

Signal

Charge, 24 h

Odometer

14,882 km

Firmware

2.4.1

Pack temperature 34 °C; normal. Charge tone online.

Charge, last 24 hours

State of charge for KDA 441Y over the last 24 hours

Charge sessions

Recent charge sessions for KDA 441Y
SessionSourceStartedDurationEnergyChargeStatus
1790129977-270SourceDC fast23 Sept 2026, 05:19Duration42mEnergy2.164kWhCharge32% → 96%StatusCompletedCharge complete
1789966795-269SourceDC fast21 Sept 2026, 07:59Duration14mEnergy0.790kWhCharge41% → 64%StatusInterruptedCharger fault
1789897940-268SourceDC fast20 Sept 2026, 12:52Duration44mEnergy2.263kWhCharge29% → 96%StatusCompletedCharge complete
1789842047-267SourceAC home19 Sept 2026, 21:20Duration4h 54mEnergy2.858kWhCharge14% → 99%StatusCompletedCharge complete
1789734475-266SourceAC home18 Sept 2026, 15:27Duration4h 1mEnergy2.365kWhCharge23% → 93%StatusCompletedCharger removed
All sessions for KDA 441Y

Telemetry

Pack voltage
72.4 V
Pack current
-18.2 A
Cell spread
18 mV
GPS fix
good · ±4 m
Signal
−74 dBm
Buffered records
0
Energy in
1,241 kWh
Energy out
2,034 kWh
Regen / unmetered
88 kWh / 0 kWh
Device ID
CHJ-DEV-00A1
Asset ID
CHJ-AST-0041
Firmware
2.4.1

Hardware

Telematics device fitted to this vehicle

Device type
CHJ-T1 Telematics
Hardware version
T1 rev C
Device ID
CHJ-DEV-00A1
ESP32 MAC
24:0A:C4:84:DF:57
Heartbeat interval
5 min
Telemetry interval
120 s
Speed limit
60 km/h

Firmware

ESP32
2.4.1
STM32
1.8.2
  1. ESP32 2.4.0 → 2.4.1

    3 h ago
    Installed

Activity

Events, faults and commands, newest first

  1. CHARGE_SESSION_CLOSED

    Info

    Charging session completed - 14.2 kWh delivered in 3 h 18 min

    3 h ago
  2. Device info · Naomi Kamau

    Confirmed
    1 d ago

Commands

Control
Diagnostics

Command history

  1. Device infoConfirmed
    1 d ago
    1. Sent: done
    2. Acknowledged: done
    3. Confirmed: done
    Naomi Kamaucmd_seed_005

Location

Loading map…

-1.2921, 36.8219

Inside: Nairobi CBD & Westlands

Contract & enforcement

  1. CurrentCurrent
  2. Reminder sentReminder sent
  3. Warning issuedWarning issued
  4. Speed restrictedSpeed restricted
  5. Immobilisation scheduledImmobilisation scheduled
  6. ImmobilisedImmobilised

Rung 1 of 6 · Current

36-Week Standard

Current

22 of 36 paid · 61% · 14 to go

Balance
Ksh 284,000
Weekly
Ksh 20,000
Next due
14 Sept 2026
Financier
Stanbic East Africa Capital

Battery pack

CHJ-PK-0041NMC · 3.2 kWh · In vehicle
State of health94%

412 cycles

  • 1Cell 1: 3.616 volts
  • 2Cell 2: 3.617 volts
  • 3Cell 3: 3.611 volts, lowest
  • 4Cell 4: 3.620 volts
  • 5Cell 5: 3.629 volts, highest
  • 6Cell 6: 3.623 volts
  • 7Cell 7: 3.613 volts
  • 8Cell 8: 3.618 volts
  • 9Cell 9: 3.620 volts
  • 10Cell 10: 3.622 volts
  • 11Cell 11: 3.613 volts
  • 12Cell 12: 3.619 volts
  • 13Cell 13: 3.626 volts
  • 14Cell 14: 3.625 volts
  • 15Cell 15: 3.624 volts
  • 16Cell 16: 3.625 volts
  • 17Cell 17: 3.627 volts
  • 18Cell 18: 3.620 volts
  • 19Cell 19: 3.622 volts
  • 20Cell 20: 3.617 volts

Min 3.611 VMax 3.629 VSpread 18 mV

Driver

Name
James Ochieng
Phone
+254 712 344 091
Status
Active
KYC
Verified
On-time payments
96%
Last 7 days
64 trips · 812 km
Operator
Nairobi BodaBoda Alliance
Driver since
06 Oct 2025

Device events

Recent device events for KDA 441Y

TimeEventSeverityReading
  • Timejust nowEventDeep telemetrySeverityInfoReading78% · 72.4 V · 34 °CDetails for Deep telemetry

    Battery

    Charge
    78%
    Health
    94%
    Voltage
    72.4 V
    Current
    -17.9 A
    Temperature
    34 °C
    Cell spread
    19 mV

    Device message

    Device message, field by field
    FieldValue
    DeviceCHJ-DEV-00A1
    Device time23 Sept 2026, 07:37
    Sequence0
    Message typeTelemetry deep
    Pack voltage72.4 V
    Pack current-17.9 A
    Temperature34 °C
    Health94%
    Cell spread19 mV
    Cell voltages20 readings · 3,611–3,630 mV
    1. 1 3,619 mV
    2. 2 3,630 mV
    3. 3 3,620 mV
    4. 4 3,619 mV
    5. 5 3,616 mV
    6. 6 3,621 mV
    7. 7 3,615 mV
    8. 8 3,622 mV
    9. 9 3,616 mV
    10. 10 3,618 mV
    11. 11 3,616 mV
    12. 12 3,623 mV
    13. 13 3,611 mV
    14. 14 3,620 mV
    15. 15 3,625 mV
    16. 16 3,615 mV
    17. 17 3,616 mV
    18. 18 3,626 mV
    19. 19 3,614 mV
    20. 20 3,625 mV
    Connectivity firmware2.4.1
    Motor-control firmware1.8.2
  • Timejust nowEventStandard telemetrySeverityInfoReading78% · 72.5 V · 34 °CDetails for Standard telemetry

    Battery

    Charge
    78%
    Health
    94%
    Voltage
    72.5 V
    Current
    -17.8 A
    Temperature
    34 °C
    Cell spread
    19 mV

    Device message

    Device message, field by field
    FieldValue
    DeviceCHJ-DEV-00A1
    Device time23 Sept 2026, 07:37
    Sequence0
    Message typeTelemetry std
    Charge78%
    Speed28 km/h
    Latitude-1.292
    Longitude36.822
    Odometer14,882 km
    StateDischarging
  • Timejust nowEventHeartbeatSeverityInfoReadingHeartbeat · -74 dBm · 0 bufferedDetails for Heartbeat

    Device message

    Device message, field by field
    FieldValue
    DeviceCHJ-DEV-00A1
    Device time23 Sept 2026, 07:37
    Sequence0
    Message typeHeartbeat
    Signal-74 dBm
    Buffered records0
    Connectivity firmware2.4.1
  • Time2 min agoEventStandard telemetrySeverityInfoReading78% · 72.4 V · 34 °CDetails for Standard telemetry

    Battery

    Charge
    78%
    Health
    94%
    Voltage
    72.4 V
    Current
    -17.8 A
    Temperature
    34 °C
    Cell spread
    19 mV

    Device message

    Device message, field by field
    FieldValue
    DeviceCHJ-DEV-00A1
    Device time23 Sept 2026, 07:35
    Sequence1
    Message typeTelemetry std
    Charge78%
    Speed28 km/h
    Latitude-1.292
    Longitude36.822
    Odometer14,882 km
    StateDischarging
  • Time4 min agoEventStandard telemetrySeverityInfoReading79% · 72.5 V · 33 °CDetails for Standard telemetry

    Battery

    Charge
    79%
    Health
    94%
    Voltage
    72.5 V
    Current
    -18.4 A
    Temperature
    33 °C
    Cell spread
    18 mV

    Device message

    Device message, field by field
    FieldValue
    DeviceCHJ-DEV-00A1
    Device time23 Sept 2026, 07:33
    Sequence2
    Message typeTelemetry std
    Charge79%
    Speed28 km/h
    Latitude-1.292
    Longitude36.822
    Odometer14,882 km
    StateDischarging
  • Time5 min agoEventHeartbeatSeverityInfoReadingHeartbeat · -74 dBm · 0 bufferedDetails for Heartbeat

    Device message

    Device message, field by field
    FieldValue
    DeviceCHJ-DEV-00A1
    Device time23 Sept 2026, 07:32
    Sequence1
    Message typeHeartbeat
    Signal-74 dBm
    Buffered records0
    Connectivity firmware2.4.1
  • Time6 min agoEventStandard telemetrySeverityInfoReading79% · 72.4 V · 33 °CDetails for Standard telemetry

    Battery

    Charge
    79%
    Health
    94%
    Voltage
    72.4 V
    Current
    -18.3 A
    Temperature
    33 °C
    Cell spread
    19 mV

    Device message

    Device message, field by field
    FieldValue
    DeviceCHJ-DEV-00A1
    Device time23 Sept 2026, 07:31
    Sequence3
    Message typeTelemetry std
    Charge79%
    Speed28 km/h
    Latitude-1.292
    Longitude36.822
    Odometer14,882 km
    StateDischarging
  • Time8 min agoEventStandard telemetrySeverityInfoReading80% · 72.5 V · 34 °CDetails for Standard telemetry

    Battery

    Charge
    80%
    Health
    94%
    Voltage
    72.5 V
    Current
    -17.8 A
    Temperature
    34 °C
    Cell spread
    18 mV

    Device message

    Device message, field by field
    FieldValue
    DeviceCHJ-DEV-00A1
    Device time23 Sept 2026, 07:29
    Sequence4
    Message typeTelemetry std
    Charge80%
    Speed28 km/h
    Latitude-1.292
    Longitude36.822
    Odometer14,882 km
    StateDischarging
  • Time10 min agoEventStandard telemetrySeverityInfoReading81% · 72.5 V · 33 °CDetails for Standard telemetry

    Battery

    Charge
    81%
    Health
    94%
    Voltage
    72.5 V
    Current
    -17.5 A
    Temperature
    33 °C
    Cell spread
    16 mV

    Device message

    Device message, field by field
    FieldValue
    DeviceCHJ-DEV-00A1
    Device time23 Sept 2026, 07:27
    Sequence5
    Message typeTelemetry std
    Charge81%
    Speed28 km/h
    Latitude-1.292
    Longitude36.822
    Odometer14,882 km
    StateDischarging
  • Time10 min agoEventHeartbeatSeverityInfoReadingHeartbeat · -74 dBm · 0 bufferedDetails for Heartbeat

    Device message

    Device message, field by field
    FieldValue
    DeviceCHJ-DEV-00A1
    Device time23 Sept 2026, 07:27
    Sequence2
    Message typeHeartbeat
    Signal-74 dBm
    Buffered records0
    Connectivity firmware2.4.1
  • Time12 min agoEventStandard telemetrySeverityInfoReading81% · 72.6 V · 35 °CDetails for Standard telemetry

    Battery

    Charge
    81%
    Health
    94%
    Voltage
    72.6 V
    Current
    -18.7 A
    Temperature
    35 °C
    Cell spread
    20 mV

    Device message

    Device message, field by field
    FieldValue
    DeviceCHJ-DEV-00A1
    Device time23 Sept 2026, 07:25
    Sequence6
    Message typeTelemetry std
    Charge81%
    Speed28 km/h
    Latitude-1.292
    Longitude36.822
    Odometer14,882 km
    StateDischarging
  • Time14 min agoEventStandard telemetrySeverityInfoReading82% · 72.7 V · 35 °CDetails for Standard telemetry

    Battery

    Charge
    82%
    Health
    94%
    Voltage
    72.7 V
    Current
    -17.7 A
    Temperature
    35 °C
    Cell spread
    16 mV

    Device message

    Device message, field by field
    FieldValue
    DeviceCHJ-DEV-00A1
    Device time23 Sept 2026, 07:23
    Sequence7
    Message typeTelemetry std
    Charge82%
    Speed28 km/h
    Latitude-1.292
    Longitude36.822
    Odometer14,882 km
    StateDischarging
  • Time15 min agoEventHeartbeatSeverityInfoReadingHeartbeat · -74 dBm · 0 bufferedDetails for Heartbeat

    Device message

    Device message, field by field
    FieldValue
    DeviceCHJ-DEV-00A1
    Device time23 Sept 2026, 07:22
    Sequence3
    Message typeHeartbeat
    Signal-74 dBm
    Buffered records0
    Connectivity firmware2.4.1
  • Time16 min agoEventStandard telemetrySeverityInfoReading82% · 72.7 V · 34 °CDetails for Standard telemetry

    Battery

    Charge
    82%
    Health
    94%
    Voltage
    72.7 V
    Current
    -17.8 A
    Temperature
    34 °C
    Cell spread
    16 mV

    Device message

    Device message, field by field
    FieldValue
    DeviceCHJ-DEV-00A1
    Device time23 Sept 2026, 07:21
    Sequence8
    Message typeTelemetry std
    Charge82%
    Speed28 km/h
    Latitude-1.292
    Longitude36.822
    Odometer14,882 km
    StateDischarging
  • Time18 min agoEventStandard telemetrySeverityInfoReading83% · 72.6 V · 34 °CDetails for Standard telemetry

    Battery

    Charge
    83%
    Health
    94%
    Voltage
    72.6 V
    Current
    -17.9 A
    Temperature
    34 °C
    Cell spread
    17 mV

    Device message

    Device message, field by field
    FieldValue
    DeviceCHJ-DEV-00A1
    Device time23 Sept 2026, 07:19
    Sequence9
    Message typeTelemetry std
    Charge83%
    Speed28 km/h
    Latitude-1.292
    Longitude36.822
    Odometer14,882 km
    StateDischarging
  • Time20 min agoEventStandard telemetrySeverityInfoReading83% · 72.6 V · 33 °CDetails for Standard telemetry

    Battery

    Charge
    83%
    Health
    94%
    Voltage
    72.6 V
    Current
    -18.3 A
    Temperature
    33 °C
    Cell spread
    18 mV

    Device message

    Device message, field by field
    FieldValue
    DeviceCHJ-DEV-00A1
    Device time23 Sept 2026, 07:17
    Sequence10
    Message typeTelemetry std
    Charge83%
    Speed28 km/h
    Latitude-1.292
    Longitude36.822
    Odometer14,882 km
    StateDischarging
  • Time20 min agoEventHeartbeatSeverityInfoReadingHeartbeat · -74 dBm · 0 bufferedDetails for Heartbeat

    Device message

    Device message, field by field
    FieldValue
    DeviceCHJ-DEV-00A1
    Device time23 Sept 2026, 07:17
    Sequence4
    Message typeHeartbeat
    Signal-74 dBm
    Buffered records0
    Connectivity firmware2.4.1
  • Time22 min agoEventStandard telemetrySeverityInfoReading84% · 72.8 V · 34 °CDetails for Standard telemetry

    Battery

    Charge
    84%
    Health
    94%
    Voltage
    72.8 V
    Current
    -18.1 A
    Temperature
    34 °C
    Cell spread
    19 mV

    Device message

    Device message, field by field
    FieldValue
    DeviceCHJ-DEV-00A1
    Device time23 Sept 2026, 07:15
    Sequence11
    Message typeTelemetry std
    Charge84%
    Speed28 km/h
    Latitude-1.292
    Longitude36.822
    Odometer14,882 km
    StateDischarging
  • Time24 min agoEventStandard telemetrySeverityInfoReading84% · 72.6 V · 34 °CDetails for Standard telemetry

    Battery

    Charge
    84%
    Health
    94%
    Voltage
    72.6 V
    Current
    -18.5 A
    Temperature
    34 °C
    Cell spread
    16 mV

    Device message

    Device message, field by field
    FieldValue
    DeviceCHJ-DEV-00A1
    Device time23 Sept 2026, 07:13
    Sequence12
    Message typeTelemetry std
    Charge84%
    Speed28 km/h
    Latitude-1.292
    Longitude36.822
    Odometer14,882 km
    StateDischarging
  • Time25 min agoEventHeartbeatSeverityInfoReadingHeartbeat · -74 dBm · 0 bufferedDetails for Heartbeat

    Device message

    Device message, field by field
    FieldValue
    DeviceCHJ-DEV-00A1
    Device time23 Sept 2026, 07:12
    Sequence5
    Message typeHeartbeat
    Signal-74 dBm
    Buffered records0
    Connectivity firmware2.4.1
Showing 20 frames · Page 1 of 2
12